Key Takeaways
- Approved geographic atrophy treatment options in the US make regular monitoring more clinically meaningful.
- Fundus autofluorescence (FAF) and OCT answer different questions, and most workflows use both.
- Comparable follow-up depends on a baseline image and the same platform and protocol over time.
- Equipment choices should follow your patient flow and referral pattern, not a feature list.
- Follow official guidelines, such as the AAO Preferred Practice Pattern, for referral and follow-up intervals.
A patient with dry AMD sits down in your chair and asks, “I read that there’s something new. Is there anything for me?”
A few years ago, the honest answer in most practices was to monitor and wait. Today the conversation is different. Treatment options for geographic atrophy (GA) now exist, and that raises the value of every image you take.
This post covers what GA is, where treatment stands, which tests show progression, and how to build a follow-up routine your practice can repeat. It also covers equipment questions for practice owners and managers. It is written for eye care professionals and does not replace clinical judgment or official guidelines.
What Geographic Atrophy Is and Why It Matters Now
Many of your dry AMD patients will never develop GA. The ones who do need a different level of attention.
Geographic Atrophy in Dry AMD
GA is an advanced form of dry age-related macular degeneration. It involves the loss of areas of the outer retina and the retinal pigment epithelium (RPE). These lesions can grow over time and affect central vision.
Why Treatment Options Change the Exam Routine
When there was nothing to offer, monitoring was mostly about documenting decline. With treatment options available, monitoring supports real decisions. These include when to refer, how to describe lesion changes, and how to communicate with the retina specialist.
That shift puts more weight on image quality, consistency, and records you can compare year to year.
Treatment Options Reaching Patients
This section is an overview for clinicians. It is not a treatment recommendation for any individual patient.
Complement Inhibitors for Slowing Progression
The first approved GA therapies are complement inhibitors given by intravitreal injection. They target parts of the complement system, which is overactive in GA. They aim to slow lesion growth. They do not restore lost tissue.
In the US, the FDA has approved two: Syfovre (pegcetacoplan) and Izervay (avacincaptad pegol). Both are approved for GA secondary to AMD. Labels carry specific warnings, including the risk of neovascular AMD, so injection decisions belong with the treating retina specialist.
Europe looks different. The EMA issued a final opinion in September 2024 recommending refusal of marketing authorisation for Syfovre. The Izelvay application was withdrawn in October 2024. Regulatory status can change, so check the current FDA and EMA pages before you quote any of this to patients or colleagues.
Retinal Implants and What PRIMA Means for the Field
A different approach is replacing function rather than slowing loss. The PRIMA retinal implant is a subretinal device studied in patients with atrophic dry AMD. The results appeared in the New England Journal of Medicine, and Science Corporation, the developer, has published information on the device.
For the details, read our post on how .
For most practices, the practical point is the same. More options for advanced disease means more reason to document the disease well.
How to Monitor Geographic Atrophy in Your Practice
No single test tells the whole story. Each one shows something different.
Fundus Autofluorescence for Lesion Size and Borders
FAF is the workhorse for GA lesions. Atrophic areas lose RPE and its lipofuscin, so they appear dark against the surrounding retina. That contrast makes the lesion’s borders and size easier to see and measure.
FAF is useful because it gives you an area you can compare across visits. Margins and the pattern around the lesion can also be reviewed with the retina specialist.
OCT for Structural Changes
OCT shows the retinal layers in cross section. In GA, it can show thinning or loss of the outer retina and RPE, along with other structural features. It also helps you check for signs that need prompt attention, such as fluid, which can point to neovascular conversion.
If you are comparing devices, our guide on covers the main decision points.
Color Fundus Photos, Visual Acuity, and Home Monitoring
These tests complement the imaging above:
- Color fundus photos document the overall appearance of the macula and are easy to compare over time.
- Visual acuity records function, but it can stay stable while a lesion grows outside the fovea. Treat it as one data point.
- Home monitoring, such as an Amsler grid or a validated app, can prompt patients to report changes. It supports the exam but does not replace it.
None of these tests guarantees early detection of change. Use them together.
Equipment Checklist for a GA Monitoring Workflow
The table below maps each test to what it shows and the equipment behind it.
| Test | What it shows | Equipment needed |
|---|---|---|
| Fundus autofluorescence (FAF) | Atrophic areas as dark regions; lesion size and borders | Fundus camera with FAF, or a confocal imaging platform with FAF |
| OCT | Retinal layer structure, outer retina and RPE changes, fluid | Spectral-domain or swept-source OCT with follow-up software |
| Color fundus photography | Overall macular appearance; baseline documentation | Fundus camera |
| Visual acuity | Functional status at each visit | Standard chart or digital acuity system |
| Home monitoring | Patient-reported changes between visits | Amsler grid or validated app (patient-owned) |
What to Look for in an OCT
Focus on features that affect daily use:
- Image resolution and clarity, especially through the common media opacities in older patients.
- Eye tracking, which helps repeat scans land on the same location.
- Follow-up comparison, so a new scan can be matched to the baseline.
- Analysis software, including how it displays layers and handles retinal thickness maps.
Ask vendors to demonstrate these features on real patient-style scans. Verify specifications in writing rather than relying on brochures.
Fundus Cameras With Autofluorescence
A fundus camera with FAF makes sense when you want lesion imaging and color documentation in one device. It can fit practices that see many dry AMD patients and already have OCT.
Building a Follow-Up Routine
A routine only works if your team can run it the same way every time. Keep it simple.
Baseline Images and Comparable Follow-Up Scans
Capture a full baseline at the first GA visit: FAF, OCT, and color photos. Then use the same platform and protocol at each follow-up.
A few habits help:
- Use the same device and scan pattern whenever possible.
- Label eyes and dates consistently in your imaging system.
- Have the same technician or a written protocol guide image capture.
- Keep images accessible to the whole care team.
Different devices can produce different appearances and measurements. That makes cross-platform comparison unreliable.
When to Refer to a Retina Specialist
Referral criteria should follow official guidance. The AAO Preferred Practice Pattern for AMD is the standard reference for US practices.
In general terms, consider prompt referral when imaging suggests new fluid or hemorrhage, when a patient reports sudden or marked visual change, or when GA is documented and the patient may be a candidate for treatment discussion. Your referral partners can tell you what images and reports they want to see.
New, Refurbished, or Bundled Retina Equipment
Your purchasing path affects cost, support, and how quickly you can start.
- New equipment offers current software, full warranty, and manufacturer support.
- Refurbished equipment can lower the entry cost, but check software versions, service history, and warranty terms.
- Bundled purchases, such as OCT with a fundus camera, can simplify service, training, and data integration.
Budgeting for OCT and Fundus Imaging Together
Think in terms of total cost of ownership instead of the purchase price alone. Include:
- Installation and staff training
- Software licenses and updates
- Service contracts and response times
- Image storage and integration with your EHR
- Expected patient volume and reimbursement
A lower-priced device with weak support can cost more over time. Ask each vendor for a written breakdown.
FAQ
Can geographic atrophy be reversed?
Current approved treatments aim to slow progression, not reverse existing damage. Lost retinal tissue does not regrow. Research on other approaches, including implants and cell-based therapies, is ongoing. Check official sources for current status.
How often should patients with geographic atrophy be monitored?
It depends on the case and the treating specialist. Follow the AAO Preferred Practice Pattern and your retina partner’s recommendations rather than a fixed interval from a blog post.
Is OCT or fundus autofluorescence better for monitoring GA?
Neither is better overall. FAF is strong for lesion area and borders. OCT is strong for structure and for spotting fluid or other changes. They complement each other.
Does a small practice need both?
It depends on your patient flow and referral pattern. If you manage many dry AMD patients in-house, having both can streamline care. If you refer most advanced cases quickly, one well-supported device plus a strong referral relationship may be enough. Review your volume, your referral partners, and your budget before deciding.
Conclusion
Three points to take away:
- Monitoring now carries more weight. Approved GA treatment options make accurate documentation more valuable.
- Use complementary tests. FAF shows the lesion, OCT shows structure, and photos and acuity add context.
- Consistency beats complexity. Use baseline images, the same platform, and clear referral criteria.
If you’re planning or upgrading your retina imaging setup, talk to Seven about OCT and retinal imaging equipment that fits your practice.
This article is for educational purposes for eye care professionals. It does not provide medical advice or treatment recommendations for individual patients. Always consult current FDA labeling and official clinical guidelines.